Resistance meter 5000V/250GOM SEW 2803IN
2803IN / SEW - Taiwan
- Test voltage (DCV): 0.5kV/1kV/2.5kV/5kV
- Measurement range: 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
- Accuracy: 0-50GΩ : ±3% rdg; 50-250GΩ : ±5% rdg
- Dimensions: 170(L) × 120(W) × 95(D)mm
- Weight: 930g
- Power: 1.5V(AA) × 8
- Standard: EN 61010-1 ; EN 61326-1
0 ₫ 0.0 VND
SEW PM15 pressure and power gauge
PM-15 / SEW - Taiwan
- AC voltage: 100-240Vrms ; Accuracy ±1%
- AC current: 15Arms; Accuracy ±1%
- Power: 0-3750W; Accuracy ±1%
- Power factor: 0.001-1
- Frequency: 45-65Hz / ±1%
- Cost: 0-9999999 $
- Power consumption: 0-99999 kWh
- Price setting: 0-99,999 kWh,cents/kWh
- Time: 1,8,12,24 Hours / 2,5,7,14,28 Days
- Fuse: 15A/250V
- Dimensions: 135(L) x 80(W) x 35(D) mm
- Weight: 200g
- Standard: EN 61010-1 ; EN 61326-1
0 ₫ 0.0 VND
DALI T8 Thermal Camera
T-8 / DALI - China
- Temperature measurement range from -200C to 6500C
- Temperature measurement accuracy:≤± 2 0C
- Spectral range: 8-14 μm
- Long-distance measurement ability: Capable of capturing heat and clear images from the camera position to heat points on electric poles > 14m high
- Thermal image resolution: 384x288
- Thermal imaging point resolution: 1.37 mrad
- Display results directly on the screen.
- When taking photos, the maximum temperature value and minimum temperature value of the thermal imaging area are displayed on the screen.
- Ability to circle the thermal imaging area to display the maximum temperature value, minimum temperature value, and average temperature value of the thermal imaging area
- Working temperature: -15 0C to +50 0C
- Storage temperature: -400 C to +700 C
- Working environment humidity: 10% to 95%
- Image format in one of the following formats: JPEG/JPG/JPE/BMP/GIF/DIB/PNG/TIF/TI/FF saved directly on camera memory or external memory card, easy to download to computer and read with popular application software such as Microsoft Office, ACD See, Adobe Acrobat...
- Storage memory: save to 8GB memory card
- Safety standards according to: CSA (USA): c22.2 No.61010-1-04, UL:UL STD 61010-1 (2nd Edition) ISA: 82.02.01
- Vibration resistance: 2g, IEC 68-2-6
0 ₫ 0.0 VND
Low pressure tester 50-1000VAC SEW LVD-15
LVD-15 / SEW - Taiwan
- Detection voltage: 50V~1000V AC
- Working frequency: 50~500 Hz
- Dimensions: 142(L) × 28(W) × 27(D)mm
- Weight:. 45g
- Power: 2 x 1.5V (AAA)
- There is a bright LED light and an audible alarm when there is voltage.
- ON/OFF switch for longer battery life.
0 ₫ 0.0 VND
SEW LVD-17 electrical tester
LVD-17 / SEW - Taiwan
- Detection voltage: 50V~1000V AC
- Measurement type: CAT IV 1000V
- Frequency: 50~500 Hz
- Operating temperature: 0~40°C
- Altitude: maximum 2000m
- Bright LED light and audible alarm when voltage is present.
- Dimensions: 142(L) × 28(W) × 27(D)mm
- Weight: 39g
- Power: 2 x 1.5V (AAA)
0 ₫ 0.0 VND
Hioki 3280-10F AC Clamp Meter
3280-10F / HIOKI - Japan
- AC current: 0-1000 A, 3 scales. Can measure up to 4200A when used with the Hioki CT6280 extension ring
- DC voltage: 0-600 V, 5 scales
- AC voltage: 0-600 V, 4 scales
- Resistance: 0-42.00 MΩ, 6 scales
- Continuous circuit: buzzer at threshold ≤ (50 Ω ± 40 Ω)
- Wire clamp diameter: φ 33 mm
- Dimensions: (WxHxD) 57x175x16 mm
- Weight: 100g
0 ₫ 0.0 VND
Hioki 3288 Clamp Meter
3288 / HIOKI - Japan
- Measure current DC100.0/ 1000 A
- Measure AC current: 100.0/ 1000 A
- Measure DC voltage: 419.9 mV to 600 V, 5 scales
- AC voltage measurement: 419.9 mV to 600 V, 4 scales
- Resistance measurement: 419.9 Ω to 41.99 MΩ, 6 scales
- Check continuity: resistance ≤ (50 Ω ±40 Ω)
- Wire clamp diameter: φ 35 mm
0 ₫ 0.0 VND
Hioki DT4282 Multifunctional Electrical Measurement Device
DT4282 / HIOKI - Japan
- DC voltage measurement feature: 60 mV to 1000 V, 6 scales
- AC voltage measurement feature: 60 mV to 1000 V, 6 scales
- DC / AC voltage measurement mode: 6V to 1000 V, 4 scales
- DC current measurement feature: 600 μA to 10 A, 6 scales
- AC current measurement feature: 600 μA to 10 A, 6 scales
- Resistance measurement feature: 60 Ω to 600 MΩ, 8 scales
- Capacitance measurement feature: 1 nF to 100 mF, 9 ranges
- Check continuity: 20/50/100/500 Ω
- Diode test:  Open terminal voltage: ≤4.5 V, Test current: ≤1.2 mA
0 ₫ 0.0 VND
Kyoritsu 8128 Clamp meter (5A - Max.50A)
8128 / Kyoritsu - Japan
- Diameter of pliers: Ø24mm
- Current measuring range: AC 5A (Max.50A)
- Output voltage: AC 50mV/5A
- Phase shift: ±2.0º (45 – 65Hz)
- Output impedance: About 20Ω
- Optional accessories: Jack 7146; Extension cord 7185
0 ₫ 0.0 VND
Fluke 1630-2 FC Earth Clamp Meter
1630-2 FC/ Fluke
- Maximum ground voltage: 1000 V
- Digital LCD display: 9999 counts
- Reference temperature: 23 °C ±5 °C (73 °F ±9 °F)
- Frequency range: 40 Hz to 1 kHz
- Operating temperature: -10 °C to +50 °C
- Dimensions (LxWxH): 283x105x48 mm
- Weight: 880g (31 oz)
- Standards: IEC/EN 61010-1 ; IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V ; IEC/EN 61557-13 ; IEC/EN 61557-5 ; IEC/EN 61557-5
0 ₫ 0.0 VND
Hioki 3280-70F AC Clamp Meter
3280-70F / HIOKI - Japan
- Resistance measurement: 420.0 Ω to 42.00 MΩ, 6 ranges (±2% rdg)
- AC current measurement (50-60Hz): 42.00 to 4200A
- DC voltage measurement: 420.0 mV to 600 V, 5 ranges (±1.0% rdg)
- AC voltage measurement (50 to 500 Hz): 4.000 V to 600 V, 4 ranges (±1.8% rdg)
- Continuity test: Buzzer at threshold ≤(50Ω ± 40Ω)
- Wire clamp diameter: φ 33 mm
- Dimensions: (WxHxD) 57x175x16 mm
- LCD display: Max. 4199 digits
- Weight: 100g
0 ₫ 0.0 VND
Elcometer B112-1B Wet Paint Comb (25-3000µm)
B112-1B / Elcometer / UK
Measuring range: 25 - 3000µm
(25, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 1000, 1100, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000µm)
- Dimensions: 75 x 65 x 1mm
- Weight Quantity: 20g
0 ₫ 0.0 VND
High Voltage Detector GD-HT9100B
GD-HT9100B / China
- Voltage range: 0.1kV~220kV(3kV-6.3kV-10kV-35kV-66kV-110kV-220kV)
- LCD display: 47mm x 28.5mm, with backlight
- Audible alarm and double red flash
- Display speed: 2 times/second
- Auto power off: After 15 minutes of non-use
- Clamp diameter: φ60mm (1800B)
- Dimensions: Receiver: 78×165×42mm; Detector: 300×237×85mm
- Insulation pole: Maximum diameter Ø38mm; Length: 1050mm (retracted), 4500mm (extended)
- Weight: 5.6kg (including insulating pole and accessories)
0 ₫ 0.0 VND
KYORITSU 2001A Multimeter
2001A / Kyoritsu
- DC V measurement range: 340.0mV / 3.400 / 34.00 / 340.0 / 600V
- AC V measurement range: 3.400 / 34.00 / 340.0 / 600V
- DC A measurement range: 100.0A ±2%rdg±5dgt
- AC A measurement range: 100.0A ±2%rdg±5dgt (50/60Hz)
- Ω measurement: 340.0Ω / 3.400 / 34.00 / 340.0kΩ / 3.400 / 34.00MΩ
- Power supply: R03 (AAA) (1.5V) × 2
- Dimensions: 128(L) × 92(W) × 27(D)mm
- Weight: 220g
Standard: IEC 61010-1 CAT III 300V, CAT II 600V; IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581 (RoHS)
0 ₫ 0.0 VND