Skip to Content

Electrical Measuring Tools

No results found for 'maximise'. Showing results for 'maximum'.
SALISBURY 4356 indirect electrical tester
- Indirect type electrical test head, does not contact electrically charged objects
- 8 test voltage ranges: Off/ 240V/ 4.2kV, 15kV, 25kV, 35kV, 69kV, 115kV, 230kV
- Signaling with LED lights and sound
- Uses 3 1.5V batteries
- Compatible with most link bars. Can be used indoors and outdoors
- Maximum detection range can be up to 230kV
0 ₫ 0.0 VND
Hioki CM4375-50 Clamp Meter
CM4375-50 / HIOKI - Japan
- DC current measurement range: 1000 A, (maximum display 999.9 A
- AC current range: 1000 A (Maximum display 999.9 A
- DC + AC current range: 1000 A
- DC capacity: 0.0 VA to 1000 kVA
- DC voltage range: 600.0 mV to 1000 V, 5 measuring ranges
- AC voltage range: 6,000 V to 1000 V, 5 measuring ranges
- DC + AC voltage range: 6,000 V to 1000 V, 5 measuring ranges
- Impedance range: 600.0 Ω to 6,000 MΩ, 5 measuring ranges
- Electrostatic capacity range: 1,000 μF to 1000 μF, 4 measuring ranges
- Frequency range: 9.999 Hz to 999.9 Hz, 3 measurement ranges
- Mount core diameter: φ34 mm (1.34 in)
0 ₫ 0.0 VND
Hioki FT6380-50 earth resistance measuring device
FT6380-50 / Hioki - Japan
- Ground resistance range: 0.20 Ω to 1600 Ω, 10 ranges
- AC current range: 20.00 mA to 60.0 A 5 ranges
- Current measurement: 100 A AC continuous, 200 A AC for 2 minutes or less
- Maximum rated ground voltage: 600 VAC
- Maximum measurable wire diameter: φ 32 mm (1.26 in)
0 ₫ 0.0 VND
Hioki IR4053-10 insulation resistance measuring device
IR4053-10 / Hioki - Japan
- Output measurement voltage: 50/125/250/500/1000 VDC. In which the 500/1000 VDC ranges can be used for solar power systems.
- Maximum resistance measurement value: 100/250/500/2000/4000 MΩ
- Lower limit resistance value: 0.05/0.125/0.25/0.5/1 MΩ
- Measure DC voltage: 4.2V to 1000V, 4 scales
- Measure AC voltage: 420V / 600V, 2 scales
0 ₫ 0.0 VND
Hioki IR4056-21 insulation resistance measuring device
IR4056-21 / Hioki - Japan
- Output measurement voltage: 50/125/250/500/1000 VDC
- Maximum resistance measurement value: 100/250/500/2000/4000 MΩ
- Lower limit resistance value: 0.05/0.125/0.25/0.5/1 MΩ
- Overload protection: AC 600V (10s) for scales < 1000 VDC and AC 1200V (10s) for scales 1000 VDC
- DC voltage measurement feature: 4.2V to 600V, 4 scales
- AC 50/60 Hz voltage measurement feature: 420V / 600V, 2 scales
- Ground wire continuity test feature: 10 Ω to 1000 Ω, 3 scales
0 ₫ 0.0 VND
Kyoritsu 2432 leakage current clamp meter
2432 / Kyoritsu - Japan
- AC current A: 4/40mA/100A
- Maximum loop voltage: 600V AC/DC ; 300V AC/DC
- Frequency: 20Hz~1kHz
- Diameter of pliers: Ø40mm
0 ₫ 0.0 VND
Fluke 1630-2 FC Earth Clamp Meter
1630-2 FC/ Fluke
- Maximum ground voltage: 1000 V
- Digital LCD display: 9999 counts
- Reference temperature: 23 °C ±5 °C (73 °F ±9 °F)
- Frequency range: 40 Hz to 1 kHz
- Operating temperature: -10 °C to +50 °C
- Dimensions (LxWxH): 283x105x48 mm
- Weight: 880g (31 oz)
- Standards: IEC/EN 61010-1 ; IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V ; IEC/EN 61557-13 ; IEC/EN 61557-5 ; IEC/EN 61557-5
0 ₫ 0.0 VND
High Voltage Detector GD-HT9100B
GD-HT9100B / China
- Voltage range: 0.1kV~220kV(3kV-6.3kV-10kV-35kV-66kV-110kV-220kV)
- LCD display: 47mm x 28.5mm, with backlight
- Audible alarm and double red flash
- Display speed: 2 times/second
- Auto power off: After 15 minutes of non-use
- Clamp diameter: φ60mm (1800B)
- Dimensions: Receiver: 78×165×42mm; Detector: 300×237×85mm
- Insulation pole: Maximum diameter Ø38mm; Length: 1050mm (retracted), 4500mm (extended)
- Weight: 5.6kg (including insulating pole and accessories)
0 ₫ 0.0 VND