Skip to Content

Electrical Measuring Tools

No results found for 'PPWR'. Showing results for 'power'.
Earth resistance meter 0-2000Om/0-2000 VAC SEW 1120ER
1120ER / SEW - Taiwan
- Measuring range: 0-20Ω / 0-200Ω / 0-2000Ω
- Resolution: 0-20Ω : 0.01Ω / 0-200Ω : 0.1Ω / 0-2000Ω : 1Ω
- Ground voltage measurement: 0-200 Vac/±(1%rdg+2dgt)
- Dimensions: 175(L) × 85(W) × 75(D)mm
- Weight: 600g
- Power: 1.5V (AA) × 8
- Standard: ICE/EN 61010-1 CAT III 200V ; IEC 61557-1 ; IEC 61557-5 ; EN 61326-1
0 ₫ 0.0 VND
Resistance meter 5000V/250GOM SEW 2803IN
2803IN / SEW - Taiwan
- Test voltage (DCV): 0.5kV/1kV/2.5kV/5kV
- Measurement range: 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
- Accuracy: 0-50GΩ : ±3% rdg; 50-250GΩ : ±5% rdg
- Dimensions: 170(L) × 120(W) × 95(D)mm
- Weight: 930g
- Power: 1.5V(AA) × 8
- Standard: EN 61010-1 ; EN 61326-1
0 ₫ 0.0 VND
Electrically check the SEW 287SVD helmet
287SVD / SEW - Taiwan
- Voltage detection distance
+ 6.6kV (3.8kV phase to ground): 40cm ± 20%
+ 11.4kV (6.6kV phase to ground): 55cm ± 20%
+ 19.7kV (11.4kV phase to ground): 80cm ± 20%
+ 22.8kV (13.2kV ​​phase to ground): 85cm ± 20%
- Water resistance: good, level IP65. Different types of AC voltage can be detected. Low power consumption. CE certification
- Warning start distance: 85cm for 22.8kV (phase – phase)
- Frequency: 50 / 60Hz. Siren: 70dB or higher at 1m distance
- Operating temperature: 0°C - 40°C. Humidity: 80%
- External dimensions: 61(L) x 62(W) x18.5(D) mm
- Weight: 70g (including battery)
- Battery: CR2032. Battery life: 50 hours of continuous use
Used to signal the user has entered a dangerous area with high voltage. Warning by sound signal (loud) and LED light. Used to wear on the wrist or on a hat.
0 ₫ 0.0 VND
Electrically check the SEW 286SVD helmet
286SVD / SEW - Taiwan
- Water resistance: good, level IP65. Different types of AC voltage can be detected. Low power consumption. CE certification
- Warning start distance: 80cm for 11.4kV (phase – phase)
- Frequency: 50 / 60Hz. Siren: 70dB or higher at 1m distance
- Operating temperature: 0°C - 40°C. Humidity: 80%
- External dimensions: 59(L) x 56(W) x18(D) mm
- Weight: 35g (including battery)
- Battery: CR2032. Battery life: 50 hours of continuous use
Used to signal the user has entered a dangerous area with high voltage. Warning by sound signal (loud) and LED light. Used to wear on the wrist or on a hat.
0 ₫ 0.0 VND
LUTRON PC6011SD clamp meter
PC6011SD / LUTRON - Taiwan
- Analyze power quality, 1-phase and 3-phase power.
- True RMS vol and current measurement.
- Measure capacity: KW, MW, GW.
- Measure AC.V: 600V, AC.A: 0 -2000A
- Display measurement chart
- Measure temperature from -100 – 1300
0 ₫ 0.0 VND
SEW 3904CL clamp meter
3904CL / SEW - Taiwan
+ ACA: 400.0/2000A /±(1.5%rdg+4dgt)
+ ACV: 400.0mV,4,000/40.00/400.0/750V /±(1.0%rdg+3dgt)
+ DCA: 400.0/2000A /±(1.5%rdg+4dgt)
+ DCV: 00.0mV/4,000/40.00/400.0/1000V /±(0.75%rdg+2dgt)
+ Ω continuity test: 400.0Ω/4.000/40.00/400.0kΩ/4.000MΩ / ±(1.5%rdg+3dgt) 40.00MΩ ±(2.0%rdg+4dgt)
+ C: 2.000/20.00/200.0nF/20.00/200.0uF/2.000mF ±(3.0%rdg+5dgt)
+ Hz: 4.000/40.00/400.0kHz/4.000/40.00MHz/ ±(1.0%rdg+2dgt)
- Plier ring: 55mm Max.
- Dimensions: 265(L) × 100(W) × 42(D)mm
- Weight: 510g
- Power source: 9V(6F22) × 1
0 ₫ 0.0 VND
KYORITSU 2055 AC/DC Clamp meter (600/1000A)
2055 / Kyoritsu - Japan
AC A : 0~600.0/1000A
DC A : 0~600.0/1000A
AC V : 6/60/600V
DC V: 600m/6/60/600V
Ω : 600/6k/60k/600k/6M/60MΩ
- Continuity check: Buzzer sounds 100Ω
- Frequency: 10/100/1k/10kHz
- Diameter of pliers: Ø40mm
- Effect frequency: 40 ~ 400Hz
- Power source: R03 (1.5V) (AAA) × 2
- Dimensions: 254(L) × 82(W) × 36(D)mm
- Weight: 310g
- Accessories: Measuring probe, Battery, Carrying case, User manual
0 ₫ 0.0 VND
Hioki CM4371-50 Clamp Meter
CM4371-50 / HIOKI - Japan
- DC current measurement range: 20.00 A/600.0 A
- AC current range: 20.00 A/600.0 A
- DC/AC current range: 20.00A/ 600.0A
- DC voltage range: 600.0 mV to 1000 V, 5 scales
- AC voltage range: 6,000 V to 1000 V, 4 scales
- DC/AC voltage range: 6,000 V to 1000 V, 4 scales
- Resistance measurement: 600.0 Ω to 600.0 kΩ, 4 scales
- Capacitance measurement: 1,000 μF to 1000 μF, 4 scales
- Frequency range: 9,999 Hz to 999.9 Hz
- Check continuity:  [ON] 25Ω±10 Ω, [OFF] 245Ω±10 Ω
- Check diode: Open voltage ≤ DC2.0V, short circuit current: 200 μA.
- Temperature measurement:  -40.0 to 400.0 ˚C
- Clamp fork tight diameter: φ33 mm
- DC power measurement: 0.0 kVA to 600 kVA (up to 1200kA when used with Hioki P2000)
0 ₫ 0.0 VND
Hioki IR4053-10 insulation resistance measuring device
IR4053-10 / Hioki - Japan
- Output measurement voltage: 50/125/250/500/1000 VDC. In which the 500/1000 VDC ranges can be used for solar power systems.
- Maximum resistance measurement value: 100/250/500/2000/4000 MΩ
- Lower limit resistance value: 0.05/0.125/0.25/0.5/1 MΩ
- Measure DC voltage: 4.2V to 1000V, 4 scales
- Measure AC voltage: 420V / 600V, 2 scales
0 ₫ 0.0 VND
Kyoritsu 2060BT Clamp meter
2060BT / Kyoritsu - Japan
- AC voltage: 1000 V
- Frequency: 40.0 – 999.9Hz
- Operating power: 40.00/400.0/1000kW
- Reactive power: 40.00/400.0/1000kVA
- Apparent power: 40.00/400.0/1000kVar
- Power factor (cos Ø): -1.000 – 0.000 – +1.000.
- Total harmonic THD-R/THD-F: 0.0% – 100.0%
- Phase order: ACV 80 – 1100V
- Clamp diameter: φ75 mm
0 ₫ 0.0 VND
Kyoritsu 2062BT Clamp meter
2062BT / Kyoritsu - Japan
- AC voltage: 1000 V
- Crest factor: 1.7 or less
- AC current: 40/400/1000 A (3 automatic measurement ranges)
- Frequency: 40.0 – 999.9Hz
- Operating power: 40.00/400.0/1000kW
- Reactive power: 40.00/400.0/1000kVA
- Apparent power: 40.00/400.0/1000kVar
- Power factor (cos Ø):  -1.000 – 0.000 – +1.000.
- Total harmonic THD-R/THD-F: 0.0% – 100.0%
- Phase order: ACV 80 – 1100V (45 – 65Hz)
- Clamp diameter: φ55mm max
0 ₫ 0.0 VND
Kyoritsu 4200 Clamp meter
4200 / Kyoritsu - Japan
- Earth resistance test:
+ Measuring range: 20Ω/200Ω/1200Ω
+ Resolution: 0.01Ω/0.1Ω/1Ω/10Ω
- AC current test:
+ Measuring range: 100mA/1A/10A/30A
+ Display range: 0.1mA/1mA/0.01A/0.1A
- Clamp diameter: Approx. Ø32mm
- Power supply: LR6/R6 (AA)(1.5V) x 4
- Dimensions: 246(L)×120(W)×54(D)mm
- Weight (without battery): 780gc
0 ₫ 0.0 VND
Kyoritsu 4202 Clamp meter
4202 / Kyoritsu - Japan
- Earth resistance test: Measuring range: 0~20Ω/ 0~200Ω/ 0~1500Ω
- AC current test: Measuring range: 100/1000mA/10A/30A
- Clamp diameter: Approx. Ø32mm
- Power supply: LR6/R6 (AA)(1.5V) x 4
- Dimensions: 246(L)×120(W)×54(D)mm
- Weight (without battery): 780g
0 ₫ 0.0 VND
Đồng hồ đo điện trở đất Kyoritsu model 4105A
4105A / Kyoritsu
- Resistance: 0~20Ω/0~200Ω/0~2000Ω
- Earth voltage [50,60Hz]: 0~200V AC
- Power supply: R6P (AA) (1.5V) × 6
- Dimensions: 105(L) × 158(W) × 70(D)mm
- Weight: 550g
- Accessories: 7095A (red-20m, yellow-10m, green-5m); 8032; 7127A ; R6P (AA)×6 ; Instruction Manual
0 ₫ 0.0 VND
Kyoritsu 2002PA Clamp Meter
2002PA / Kyoritsu
- Clamp diameter: φ 55mm
- Measuring range: 0-2000A AC
- Frequency: 40Hz to 1kHz
- Power supply: R6 (AA) (1.5V) × 2
- Dimensions: 247×105×49mm
- Weight: ~470g
- Standard: IEC 61010-1 CAT III 600V / CAT II 1000V ; IEC 61010-2-031 IEC 61010-2-032
0 ₫ 0.0 VND
Máy đo điện trở cách điện KYORITSU 3125A
3125A / Kyoritsu - Japan
- AC/DC voltage measurement: 30 ~ 600V
- Short circuit current: 1.5mA
- Test voltage: 250V/500V/1000V/2500V/5000V
- Resistance measurement range: 100.0MΩ/1000MΩ/2.00GΩ/100.0GΩ/1000GΩ
- Accuracy: ±5%rdg |±3dgt, ±20%rdg (100GΩ or more)
- Power supply: DC12V: LR14/R14 × 8pcs
- Accessories: 7165A (Line probe); 7264A (Earth probe); 7265A (Guard probe); 8019 (Hook type prod) ; 9181 (Carrying case) ; LR14×8pcs (Battery) ; User manual.
0 ₫ 0.0 VND
Kyoritsu 3165 Insulation Resistance Meter
3165/ Kyoritsu
- DC Test Voltage : 500V
- Max measurement value : 1000MΩ
- First measurement range : 1~500MΩ
- Error : |±5% rdg
- Second measurement range : 1/1000MΩ
- Error : ±10% rdg
- AC voltage : 600V
- Accuracy : |±3%
- Power supply : R6P (AA) (1.5V) × 4
- Dimensions : 90(L) × 137(W) × 40(D)mm
- Weight : 330g approx.
0 ₫ 0.0 VND
Đồng hồ đo điện trở đất Kyoritsu 4105A-H
4105A-H / Kyoritsu
- Resistance: 0~20Ω/0~200Ω/0~2000Ω
- Earth voltage [50,60Hz]: 0~200V AC
- Accuracy
+ Resistance: ±2%rdg±0.1Ω (20Ωrange)
±2%rdg±3dgt (200Ω/2000Ωrange)
+ Earth voltage: ±1%rdg±4dgt
- Power supply: R6P (AA) (1.5V) × 6
- Dimensions: 105(L) × 158(W) × 70(D)mm
- Weight: 550g
- Accessories: 7095A (red-20m, yellow-10m, green-5m); 8032; 7127A ; R6P (AA)×6 ; Instruction Manual
0 ₫ 0.0 VND
Kyoritsu 2200 Clamp Meter
2200 / Kyoritsu
- Clamp diameter: Ø33mm
- AC current: 40.00/400.0/1000A
- AC voltage: 4.000/40.00/400.0/600V
- DC voltage: 400.0mV/4.000/40.00/400.0/600V
- Resistance: 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ
- Power source: R03/LR03 (AAA) (1.5V) × 2
- Dimensions: 190(L) × 68(W) × 20(D)mm
- Weight: ~120g
- Accessories: 7107A test probe, Box 9160, R03 (AAA) × 2, Instruction Manual
- Standard: IEC 61010-1 CAT III 600V / CAT II 1000V ; IEC 61010-2-031 IEC 61010-2-032
0 ₫ 0.0 VND